Property:
- High-performance building material
- Mass per unit area : 150
- Water vapour trasmission (Sd) (m) : 0,05
- Maximum tensile force MD/CD (N/50mm) : 315/250
- Elongation MD/CD (%) : 61/66
- Resistance to tearing MD/CD (N) : 255/270
- Watertightness (class) : classe W1
- VOC emission (COV) (%(class A+)) : 0
- Temperature resistance (°C) : -40/+80
TRASPIR 150 is placed parallel to the eaves line, starting from the lower edge of the roof. The second layer must be overlapped by at least 10-20 centimeters to the previous one (depending on the slope of the roof), as indicated on the layout according to UNI 11470:2013. The sheet must be applied on continuous support with a mechanical fastening device. (ex: HAMMER STAPLER, HAND STAPLER o PNEU STAPLER). Once at the top of the roof, it is advisable for the membrane to protrude beyond the ridgeline by at least 30 centimeters to ensure a perfect overlap with the strips of the sheet that will overlap on the other side of the roof. It is also recommended that the sheets overlap by at least 30 cm even at the end joints. To achieve correct air and water sealing, we recommend the use of EASY BAND, SPEEDY BAND, FLEXI BAND, FLEXI BAND UV, SOLID BAND, PLASTER BAND, SMART BAND, FACADE BAND UV, FRONT BAND UV, FRONT BAND UV 210, DOUBLE BAND, SUPRA BAND, BUTYL BAND, OUTSIDE GLUE, FIRE SEALING, FIRE STRIPE.If there is an integrated double adhesive strip, it can replace the correct air and water sealing.